SG2016P

JetStream 16-Port Gigabit Smart Switch with 8-Port PoE+

  • 120 W PoE Budget: 8× 802.3at/af-compliant PoE+ ports with a total power supply of 120 W*.
  • Full Gigabit Ports: 8× gigabit PoE+ ports and 8× gigabit non-PoE ports provide high-speed connections.
  • Integrated into Omada SDN: Zero-Touch Provisioning**, Centralized Cloud Management, and Intelligent Monitoring.
  • Centralized Management: Cloud access and Omada app for ultra convenience and easy management.
  • Robust Security Strategies: IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm control, DHCP Snooping, 802.1X, Radius Authentication, and more.
  • Optimize Voice and Video Applications: L2/L3/L4 QoS and IGMP snooping.

Learn more about TP-Link PoE technology >

 

Learn more about Omada Cloud SDN>​

TP-Link | Omada POE

Omada 16-Port Gigabit Smart Switch with 8-Port PoE+

SG2016P

  •  

    16× Gigabit Ports
    (8× PoE+)

  •  

    120 W Total
    PoE Budget*

  •  

    Fanless Design for
    Silent Operation

  •  

    Zero-Touch
    Provisioning


  •  

    Centralized
    Management

  •  

    Omada
    App

  •  

    Static
    Routing

  •  

    Traffic
    Separation

Software Defined Networking (SDN) with Cloud Access

Remotely manage your access points, switches, and gateways across multiple sites all from a single interface.

Ceiling Mount AP
Wall Plate AP
Outdoor AP
Omada PoE Switch
Omada VPN Gateway
Cloud Access
On-premises Controllers
Omada Hardware
Controller
Or
Omada Software
Controller
Or
Omada Cloud-Based
Controller

(Subscription Required)
Internet
Web Browser
Omada App

Multiple Application Scenarios

  •  

    Surveillance

    Works with IP Cameras

  •  

    Conference Call

    Works with IP Phones

  •  

    Wi-Fi Coverage

    Works with Access Points

  •  

    Wired Connections

    Works with Non-PoE Devices such as PCs and Printers

CARACTERÍSTICAS DE HARDWARE
Estándares y Protocolos IEEE 802.3i, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3at, IEEE 802.3x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.1x
Interface • 16× 10/100/1000 Mbps RJ45 Ports (Ports 1–8 Support 802.3at/af PoE+)
• Auto-Negotiation/Auto MDI/MDIX
Medios de Red • 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m)
• 100BASE-TX/1000Base-T: UTP category 5, 5e or above cable (maximum 100m)
Cantidad de Ventiladores Fanless
Cerradura de Seguridad Física
Fuente de Alimentación • External Power Adapter (Output: 53.5 VDC/ 2.43 A)
Puertos PoE (RJ45) • Standard: 802.3af/at compliant
• PoE Ports: 8 Ports
• Power Supply: 120 W*
Dimensiones (W X D X H) 11.3 x 4.4 x 1.0 in (286 x 111.7 x 25.4 mm)
Montaje Desktop/Wall-Mounting
Consumo Máximo de energía 146.5 W (110 V/60 Hz) (with 120 W PD connected)
Disipación Máxima de Calor 499.98 BTU/hr (110 V/60 Hz) (with 120 W PD connected)
RENDIMIENTO
Capacidad de Switcheo 32 Gbps
Ancho de Banda / Backplane 16 Gbps
Tasa de Reenvío de Paquetes 23.81 Mpps
Tabla de MAC Address 8k
Paquetes de Memoria de búfer 4.1 Mbit
Jumbo Frame 9 KB
CARACTERÍSTICAS DE SOFTWARE
Calidad de servicio • 802.1p CoS/DSCP priority
• 8 priority queues
• Priority Schedule Mode
- SP (Strict Priority)
- WRR (Weighted Round Robin)
• Queue Weight Config
• Bandwidth Control
- Port/Flow-based Rating Limit
• Smoother Performance
• Storm Control
- Multiple Control Modes(kbps/ratio)
- Broadcast/Multicast/Unknown-Unicast Control
Características de L2 y L2 + • DHCP Relay
- DHCP VLAN Relay
• DHCP L2 Relay
• Link Aggregation
- Static link aggregation
- 802.3ad LACP
- Up to 8 aggregation groups and up to 8 ports
per group
• Spanning Tree Protocol
- 802.1D STP
- 802.1w RSTP
- 802.1s MSTP
- STP Security: TC Protect, BPDU Filter/Protect,
Root Protect
• Loopback Detection
• Flow Control
- 802.3x Flow Control
• Mirroring
- Port Mirroring
- CPU Mirroring
- One-to-One
- Many-to-One
- Flow-Based
- Ingress/Egress/Both
• Device Link Detect Protocol (DLDP)
• 802.1ab LLDP/ LLDP-MED
L2 Multicast • 511 IPv4, IPv6 shared multicast groups
• IGMP Snooping
- IGMP v1/v2/v3 Snooping
- Fast Leave
- IGMP Snooping Querier
- Static Group Config
• Multicast VLAN Registration (MVR)
• Multicast Filtering
• MLD Snooping
- MLD v1/v2 Snooping
- Fast Leave
- MLD Snooping Querier
- Static Group Config
• Limited IP Multicast (256 profiles and 16 entries per profile)
Características Avanzadas • Automatic Device Discovery
• Batch Configuration
• Batch Firmware Upgrading
• Intelligent Network Monitoring
• Abnormal Event Warnings
• Unified Configuration
• Reboot Schedule
Soporte IPv6 • IPv6 Dual IPv4/IPv6
• Multicast Listener Discovery (MLD) Snooping
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP)
version 6
• TCPv6/UDPv6
• IPv6 applications
- DHCPv6 Client
- Ping6
- Tracert6
- Telnet (v6)
- IPv6 SNMP
- IPv6 SSH
- IPv6 SSL
- Http/Https
- IPv6 TFTP
VLAN • VLAN Group
- Max. 4K VLAN Groups
• 802.1Q tag VLAN
• MAC VLAN: 12 Entries
• Protocol VLAN
• GVRP
• Voice VLAN
Lista de control de acceso • Support up to 230 entries
• Time-Range
- Time Slice
- Week Time-Range
- Absolute Time-Range
- Holiday
• Time-based ACL
• MAC ACL
- Source MAC
- Destination MAC
- VLAN ID
- User Priority
- Ether Type
• IP ACL
- Source IP
- Destination IP
- IP Protocol
- TCP Flag
- TCP/UDP Source Port
- TCP/UDP Destination Port
- DSCP/IP TOS
• IPv6 ACL
• Combined ACL
• Rule Operation
- Permit/Deny
• Policy Action
- Mirror
- Rate Limit
- Redirect
- QoS Remark
• ACL Rules Binding
- Port Binding
- VLAN Binding
• Actions for flows
- Mirror (to supported interface)
- Redirect (to supported interface)
- Rate Limit
- QoS Remark
Seguridad • AAA
• 802.1X
- Port-based authentication
- MAC (Host) based authentication
- Authentication Method includes PAP/EAP-MD5
- MAB
- Guest VLAN
- Support Radius authentication and
accountability
• IP/IPv6-MAC Binding
- 512 Binding Entries
- DHCP Snooping
- DHCPv6 Snooping
- ARP Inspection
- ND Detection
• IP Source Guard
- 253 Entries
- Source IP+Source MAC
• IPv6 Source Guard
- 183 Entries
- Source IPv6 Address+Source MAC
• DoS Defend
• Static/Dynamic/Permanent Port Security
- Up to 64 MAC addresses per port
• Broadcast/Multicast/Unicast Storm Control
- kbps/ratio control mode
• Port Isolation
• Secure web management through HTTPS with
SSLv3/TLS 1.2
• Secure Command Line Interface (CLI)
management with SSHv1/SSHv2
• IP/Port/MAC-based access control
IPv6 • IPv6 Static Routing and ACL
• IPv6 Dual IPv4/IPv6
• IPv6 Interface
• Multicast Listener Discovery (MLD) Snooping
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP) version 6
• TCPv6/UDPv6
• IPv6 applications
- DHCPv6 Client
- Ping6
- Tracert6
- Telnet(v6)
- IPv6 SNMP
- IPv6 SSH
- IPv6 SSL
- Http/Https
- IPv6 TFTP
MIBs • MIB II (RFC1213)
• Bridge MIB (RFC1493)
• P/Q-Bridge MIB (RFC2674)
• Radius Accounting Client MIB (RFC2620)
• Radius Authentication Client MIB (RFC2618)
• Remote Ping, Traceroute MIB (RFC2925)
• Support TP-Link private MIBs
• RMON MIB(RFC1757, rmon 1,2,3,9)
ADMINISTRACIÓN
Omada App Yes, through
• Omada Cloud-Based Controller
• OC300
• OC200
• Omada Software Controller
Centralized Management • Omada Cloud-Based Controller
• Omada Hardware Controller (OC300)
• Omada Hardware Controller (OC200)
• Omada Software Controller
Cloud Access Yes, through
• Omada Cloud-Based Controller
• OC300
• OC200
• Omada Software Controller
Zero-Touch Provisioning Yes. Requiring the use of Omada Cloud-Based Controller
Management Features • Web-based GUI
• Command Line Interface (CLI) through telnet
• SNMPv1/v2c/v3
• SNMP Trap/Inform
• RMON (1,2,3,9 groups)
• SDM Template
• DHCP/BOOTP Client
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• EEE
• SNTP
• System Log
Otros
Certificacion CE, FCC, RoHS
Contenidos del Paquete • TL-SG2016P
• Power Adapter
• Installation Guide
• Rubber Feet
Requisitos del Sistema Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
Ambiente • Operating Temperature: 0–40 ℃ (32–104 ℉);
• Storage Temperature: -40–70 ℃ (-40–158 ℉)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing

*PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.

**Zero-Touch Provisioning requires the use of Omada Cloud-Based Controller. Go to https://www.tp-link.com/en/omada-cloud-based-controller/product-list/ to confirm which models are compatible with Omada Cloud-Based Controller.

From United States?

Obtenga productos, eventos y servicios para su región.